Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Personal Protective Equipment and Dermal Exposure

Authors: Paul G. Evans; John J. McAlinden; Peter Griffin;

Personal Protective Equipment and Dermal Exposure

Abstract

Personal protective equipment (PPE) should only be used as a control measure when other measures are inappropriate or are inadequate by themselves. The person undertaking a risk assessment must exercise his or her judgment to take into account the protection afforded by the PPE. There is, therefore, considerable scope for differences in approach and it would seem sensible to eliminate these differences and ensure consistency, where possible, by reaching agreement on the attenuating effect of PPE. However, there is growing evidence that the levels of protection indicated by laboratory-based tests may not be achieved in real use situations. Studies of workplace protection suggest that the spread of contaminants inside protective clothing, including gloves, is commonplace and significant. Insufficient attention may have been paid to the effect of factors such as temperature differentials on the permeation of chemical agents through protective materials. To investigate this, a test cell was designed and built to measure the breakthrough times and subsequent permeation rate of solvents through glove materials where the temperature inside and outside the glove was representative of those that can occur in the workplace. Two chemical solvents were tested against two different glove materials at three different temperature conditions. The differences between the breakthrough times and permeation rates were measured and compared to manufacturer's test data. The practical implications are considered for risk of health and safety to the wearer.

Related Organizations
Keywords

Occupational Exposure, Materials Testing, Solvents, Temperature, Humans, Gloves, Protective, Risk Assessment, United Kingdom, Skin

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    29
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
29
Top 10%
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!