The building column design procedure should take into account the effect of frame instability. This effect can be considered by use of the effective lengths of the columns or by application of P-Delta forces. For a selected class of frames and loadings, the effect of frame instability may be ignored. Use of the effective length of columns is a reliable procedure provided that satisfactory approximations of the effective lengths of the columns can be calculated. These calculations must consider any nonsymmetry of building properties and loads, material yielding, connection flexibility, and support conditions. Application of P-Delta forces is an approximate, direct, working stress design procedure applicable to both regular and irregular frames in combination with possible complimentary bracing systems. The approximation has been verfied for a limited class of structures and use of a conservative factor of safety is recommended. Selected frames and limitations for which instability effects can be ignored are summarized.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 4 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |