Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Journal of Cardiotho...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Journal of Cardiothoracic and Vascular Anesthesia
Article . 2012 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
PubliCatt
Article . 2012
Data sources: PubliCatt
versions View all 3 versions
addClaim

A Comparison of Endotracheal Bioimpedance Cardiography and Transpulmonary Thermodilution in Cardiac Surgery Patients

Authors: Fellahi, Jean Luc; Fischer, Marc Olivier; Rebet, Olivier; Massetti, Massimo; Gérard, Jean Louis; Hanouz, Jean Luc;

A Comparison of Endotracheal Bioimpedance Cardiography and Transpulmonary Thermodilution in Cardiac Surgery Patients

Abstract

The authors hypothesized that bioimpedance cardiography measured by the Endotracheal Cardiac Output Monitor (ECOM; ConMed, Utica, NY) is a convenient and reliable method for both cardiac index (CI) assessment and prediction in fluid responsiveness.A prospective observational study.A teaching university hospital.Twenty-five adult patients.Admission to the intensive care unit after conventional cardiac surgery and investigation before and after a fluid challenge.Simultaneous comparative CI data points were collected from transpulmonary thermodilution (TD) and ECOM. Correlations were determined by linear regression. Bland-Altman analysis was used to compare the bias, precision, and limits of agreement. The percentage error was calculated. Pulse-pressure variations (PPVs) and stroke-volume variations (SVVs) before fluid challenge were collected to assess their discrimination in predicting fluid responsiveness. A weak but statistically significant relationship was found between CI(TD) and CI(ECOM) (r = 0.31, p = 0.03). Bias, precision, and limits of agreement between CI(TD) and CI(ECOM) were 0.08 L/min/m(2) (95% confidence interval, -0.11 to 0.27), 0.68 L/min/m(2), and -1.26 to 1.42 L/min/m(2), respectively. The percentage error was 51%. A nonsignificant positive relationship was found between percent changes in CI(TD) and CI(ECOM) after fluid challenge (r = 0.37, p = 0.06). Areas under the ROC curves for both PPV and SVV to predict fluid responsiveness were 0.86 (95% confidence interval, 0.67-1.06) and 0.89 (95% confidence interval, 0.74-1.04, respectively; p = 0.623).Continuous measurements of CI under dynamic conditions are consistent and easy to obtain with ECOM although not interchangeable with transpulmonary thermodilution. SVV given by ECOM is a dynamic parameter that predicts fluid responsiveness with good accuracy and discrimination.

Country
Italy
Keywords

Male, Thermodilution, Middle Aged, Cardiography, Impedance, Aged; Cardiac Output; Cardiac Surgical Procedures; Cardiography, Impedance; Electric Impedance; Female; Humans; Male; Middle Aged; Prospective Studies; Thermodilution, Electric Impedance, Humans, Female, Prospective Studies, Cardiac Output, Cardiac Surgical Procedures, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    26
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
26
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!