Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ The Journal of Extra...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
The Journal of ExtraCorporeal Technology
Article . 2005 . Peer-reviewed
License: EDP Sciences Copyright and Publication Licensing Policy
Data sources: Crossref
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 2 versions
addClaim

Temperature Inaccuracies During Cardiopulmonary Bypass

Authors: Mohammad, Salah; Robin, Sutton; Gary, Tsarovsky; Michael, Djuric;

Temperature Inaccuracies During Cardiopulmonary Bypass

Abstract

Cerebral hyperthermia caused by perfusate temperature greater than 37°C during the rewarming phase of CPB has been linked to postoperative neurologic deficits. The purpose of this study was to determine the accuracy of the coupled temperature measurement system and the CDI 500 arterial temperature sensor. Seventeen patients undergoing CPB were divided into four groups, each with a different temperature probe coupled to the oxygenator. The coupled temperature measurement system and CDI temperature sensors were compared with an indwelling probe placed in direct contact with the arterial perfusate. Blood, bladder, room and water temperatures, arterial line pressure, blood flow, and hemoglobin were recorded while the patients were supported with CPB. The actual blood temperature was significantly higher than the coupled temperature measurement system for two of the four groups (mean = 1.61°C and 0.91°C,p< 0.0001). A significant positive correlation between the actual temperature and the coupled temperature measurement system error was observed for the same two groups (r = 0.44,p< 0.0001). The actual temperature was significantly higher than the CDI temperature in all patients (mean = 1.2°C,p< 0.0001). The coupling mechanism on the oxygenator generates inconsistent temperature readings. The perfusionist should consider these inconsistencies when using coupled temperature measurements and may consider the use of a direct temperature measurement system. The CDI temperature error is probably the result of inadequate flow through the sensor. On the test circuit, the flow of 170 mL/min was inadequate for circuit temperature accuracy. The accuracy of the CDI temperature drastically improved when the flow-through the sensor was increased to approximately 400 mL/min. Thus, the perfusionist must ensure adequate flow through the sensor in order for the temperature mechanism to function properly. Finally, the perfusionist can prevent cerebral hyperthermia by not allowing water temperature to exceed 37°C, when using a coupled temperature measurement system.

Related Organizations
Keywords

Cardiopulmonary Bypass, Extracorporeal Membrane Oxygenation, Postoperative Complications, Fever, Thermometers, Materials Testing, Humans, Prospective Studies, Body Temperature, Monitoring, Physiologic, Oxygenators, Membrane

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    9
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
9
Top 10%
Average
Average
gold