doi: 10.1021/i200030a025
Current design of the fluidized bed scrubber (FBS), otherwise known as the Turbulent Contact Absorber or the Mobile Bed Contactor, is based on experience and rules of thumb. In this paper published equations on hydrodynamics and mass transfer are reviewed. From the equations a logical design procedure for the FBS Is proposed. A specimen calculation is presented to illustrate the design procedure.
Auditing and Accountability, 2200 Engineering, 2300 Environmental Science, 1501 Accounting, General Engineering, General Medicine, 1501 Accounting, Auditing and Accountability, 2507 Polymers and Plastics
Auditing and Accountability, 2200 Engineering, 2300 Environmental Science, 1501 Accounting, General Engineering, General Medicine, 1501 Accounting, Auditing and Accountability, 2507 Polymers and Plastics
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 4 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |