Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Prediction of difficult tracheal intubation

Authors: A. J. Cunningham; M. Ronayne; G. Iohom;

Prediction of difficult tracheal intubation

Abstract

Preoperative bedside screening tests for difficult tracheal intubation may be neither sensitive nor specific enough for clinical use. The aim was to investigate if a combination of the Mallampati classification of the oropharyngeal view with either the thyromental or sternomental distance measurement improved the predictive value.A total of 212 (109 male, 103 female) non-obstetric surgical patients, aged >18 yr, undergoing elective surgical procedures requiring tracheal intubation were assessed preoperatively with respect to the oropharyngeal (modified Mallampati) classification, thyromental and sternomental distances. An experienced anaesthetist, blinded to the preoperative airway assessment, performed laryngoscopy and graded the view according to Cormack and Lehane's classification.Twenty tracheal intubations (9%) were difficult as defined by a Cormack and Lehane Grade 3 or 4, or the requirement for a bougie in patients with Cormack and Lehane Grade 2. Used alone, the Mallampati oropharyngeal view, and thyromental and sternomental distances were associated with poor sensitivity, specificity and positive predictive values. Combining the Mallampati Class III or IV with either a thyromental distance <6.5cm or a sternomental distance <12.5cm decreased the sensitivity (from 40 to 25 and 20%, respectively), but maintained a negative predictive value of 93%. The specificity and positive predictive values increased from 89 and 27% respectively for Mallampati alone to 100%.The findings suggest that the Mallampati classification, in conjunction with measurement of the thyromental and sternomental distances, may be a useful routine screening test for preoperative prediction of difficult tracheal intubation.

Keywords

Male, Mouth, Laryngoscopy, Oropharynx, Anesthesia, General, Sensitivity and Specificity, Predictive Value of Tests, Preoperative Care, Intubation, Intratracheal, Humans, Female, Prospective Studies, Physical Examination, Neck

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    107
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
107
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author? Do you have the OA version of this publication?