Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Radiotherapy and Onc...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Radiotherapy and Oncology
Article . 2000 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

The ESTRO-QUALity assurance network (EQUAL)

Authors: I. Ferreira; Jean Chavaudra; Hans Svensson; André Bridier; A. Dutreix;

The ESTRO-QUALity assurance network (EQUAL)

Abstract

ESTRO has set up a Quality Assurance network (EQUAL) to check the dose delivered on axis in reference and non-reference conditions for external radiotherapy. The external audits covered by the network are based on measurements made with mailed thermoluminescent dosimeters (TLD).The TLD consist of LiF powder type DTL 937 read with a PCL 3 automatic TLD reader. The participating centres are instructed to deliver to the TLDs absorbed doses of 2 Gy calculated with the Treatment Planning System used in clinical routine. A maximum of three photon energies by participating centre have been checked with 10 on-axis points per beam. The quantities checked include the reference beam output, beam output variation with collimator opening, depth dose data and wedge transmission factor.During the 1998 EQUAL programme 102 centres have been checked corresponding to 235 beams (28 (60)Co beams and 207 X-ray beams). About 3% of the outputs in reference conditions show deviations outside tolerance level (>+/-5%). A similar rate of deviation is noted for the percentage depth doses. A rate of deviation (6%) has been observed for the beam output variation (open and wedged beams) and the wedge transmission factor. The analysis of the results shows that for 24 out of the 102 centres, a deviation outside tolerance level is observed at least in one point, mainly for the large and rectangular field sizes and for the wedged beams.The results for the EQUAL programme show the importance of a quality assurance network in Radiotherapy especially for the non reference points even if they are only located on the beam axis (In order to participate in this network, please contact EQUAL secretariat or download the attached application form ESTRO web site: Dr I.H. Ferreira or Mrs Aline Mechet, EQUAL-ESTRO, Physics Department, Institut Gustave-Roussy 39 Rue Camille Desmoulins, F-94805 Villejuif Cedex, France. e-mail:equal@igr.fr or http://www.estro.be/).

Keywords

Observer Variation, Quality Assurance, Health Care, Radiotherapy, Humans, Radiation Dosage, Radiometry, Retrospective Studies

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    102
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 1%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
102
Top 10%
Top 1%
Top 10%
bronze