Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Resuscitationarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Resuscitation
Article . 2008 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
Resuscitation
Article . 2008
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

A method to remove CPR artefacts from human ECG using only the recorded ECG

Authors: Elisabete Aramendi; Sofía Ruiz de Gauna; Jo Kramer-Johansen; Trygve Eftestøl; Unai Irusta; Jesus Ruiz;

A method to remove CPR artefacts from human ECG using only the recorded ECG

Abstract

To show the possibility of using cardiopulmonary resuscitation (CPR) artefact suppression methods that do not need additional reference signals to model CPR artefacts.A CPR suppression method based on a Kalman filter was designed. The artefact was modelled using the fundamental frequency of the compressions, estimated from the spectral analysis of the ECG. Artificial mixtures of human shockable rhythms and CPR artefacts were used to design the algorithm that was then tested on samples obtained from real out-of-hospital cardiac arrest episodes.The shock/no-shock decision of an automated external defibrillator (AED) was evaluated before and after CPR suppression for 131 shockable and 347 non-shockable samples. The sensitivity improved from 56% (95% CI, 47-64%) to 90% (95% CI, 84-94%). However, the specificity decreased from 91% (95% CI, 87-93%) to 80% (95% CI, 76-84%).CPR artefacts can be suppressed using methods based on the analysis of the ECG alone. The hardware of current AEDs does not need to be replaced, although better artefact suppression methods exist for modified AEDs with additional reference channels.

Keywords

Emergency Medical Services, Electric Countershock, Reproducibility of Results, Sensitivity and Specificity, Cardiopulmonary Resuscitation, Heart Arrest, Electrocardiography, Humans, Artifacts, Algorithms

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    47
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
47
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author? Do you have the OA version of this publication?