image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Journal of Prostheti...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Journal of Prosthetic Dentistry
Article . 2017 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Effect of locator abutment height on the retentive values of pink locator attachments: An in vitro study

Authors: Priscilla Kia Suan Sia; Radi Masri; Carl F. Driscoll; Elaine Romberg;

Effect of locator abutment height on the retentive values of pink locator attachments: An in vitro study

Abstract

Currently, no guidelines exist to help in the selection of Locator abutments for implants at different heights.The purpose of this in vitro study was to evaluate the effect of the differential heights of pairs of Locator abutments on the retention of overdentures after 6 months of simulated function.In vitro testing was performed with 4 sets of average-sized edentulous mandible analogs with 2 implants placed in the canine positions. There were 10 specimens in each of the 4 groups, with a total sample size of 40. Four groups of 2 implant-retained overdentures were fabricated, with Locator attachments at different vertical levels with differences of 0, 2, 4, and 6 mm. The overdentures were subjected to simulated function for a period corresponding to 6 months of clinical service and then tested with a universal testing machine for changes in peak load-to-dislodgement. The data were analyzed using 1-way ANOVA followed by the Tukey honest significant differences test (α=.05).Varying the heights of Locator abutments had a statistically significant effect on the retentive values of the pink Locator attachments after 6 months of simulated function (F=7.342, P=.001). The peak load-to-dislodgement ranged from 32.3 N (95% confidence interval [CI]: 26.0 to 38.6) for group 0 mm to 53.6 N (95% CI: 46.3 to 60.8) for group 6 mm. When the difference in Locator abutment heights was 2 and 4 mm, the peak load was 37.1 N (95% CI: 32.3 to 42.0) and 41.9 N (95% CI: 31.2 to 52.7). Statistical analysis revealed that the retention of group 0 mm and group 2 mm was significantly lower than group 6 mm. The retention of group 4 mm was not significantly different from groups 0 mm, 2 mm, or 6 mm.Although significant differences were found among the groups, these differences were small and may not be clinically detectable.

Keywords

Dental Prosthesis Retention, Humans, Dental Abutments, Dental Implant-Abutment Design, Dental Prosthesis, Implant-Supported, In Vitro Techniques

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    18
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
18
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!