image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Ophthalmologyarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Ophthalmology
Article . 2009 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Measurement of Goldmann Applanation Tonometer Calibration Error

Authors: Namrata Dudeja; Lingam Vijaya; Mani Baskaran; Ronnie George; Nikhil S Choudhari;

Measurement of Goldmann Applanation Tonometer Calibration Error

Abstract

To determine the frequency and possible origins of calibration errors of the Goldmann applanation tonometer and to investigate intraobserver and interobserver agreement in the measurement of such calibration errors.Evaluation of diagnostic test or technology.One hundred thirty-two slit-lamp-mounted Haag-Streit Goldmann tonometers (Model AT 900 C/M; Haag-Streit, Bern, Switzerland).Calibration error testing was performed using the standard calibration error check weight bar. A single observer tested 25 instruments on 2 consecutive days. Two observers independently measured calibration errors of another 40 instruments. A single observer performed prospective testing of the remaining Haag-Streit Goldmann tonometers, 6 months after their annual calibration by the bioengineering department of the hospital. Four months later, the same observer retested the instruments that were found to be faulty earlier.Goldmann applanation tonometer calibration error.Only 4% of Goldmann tonometers were found to be within the manufacturer's recommended calibration error tolerance (+/-0.5 mmHg) at 20 mmHg. Twenty-eight percent of instruments had calibration errors of more than +/-2 mmHg at the 20-mmHg testing level. An additional 12.12% had calibration errors of more than +/-2 mmHg at the 0- or 60-mmHg testing levels, or both. Four months after the initial testing and repair of the 53 faulty instruments, 20.75% again were found to have calibration errors of more than +/-2 mmHg at any one or more testing level(s). Intraclass correlation coefficients for intraobserver agreement at 20 mmHg were 0.57 (95% confidence interval [CI], 0.25-0.78) for positive error, 0.82 (95% CI, 0.65-0.92) for negative error, and for interobserver agreement at 20 mmHg, 0.83 (95% CI, 0.70-0.90) for positive error and 0.83 (95% CI, 0.70-0.90) for negative error.The authors found good agreement in measurement of Goldmann applanation tonometer calibration error. A significant number of instruments had clinically unacceptable calibration errors. A more frequent calibration error testing and automation of calibration error check is desirable.The authors have no proprietary or commercial interest in any materials discussed in this article.

Related Organizations
Keywords

Observer Variation, Quality Control, Tonometry, Ocular, Calibration, Humans, Reproducibility of Results, Equipment Failure, Glaucoma, Intraocular Pressure

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    35
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
35
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!