<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://www.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=undefined&type=result"></script>');
-->
</script>
pmid: 23121701
To determine the relationship between dynamic contour tonometry (DCT), Goldmann applanation tonometry (GAT) and pneumotonometry (PNT) in ocular hypertension patients (OHT) and their relationship to central corneal thickness (CCT) and ocular pulse amplitude (OPA).Sixty patients (101 eyes) with intraocular pressure (IOP) ≥21 mmHg using GAT and normal appearing optic nerve heads and normal visual fields were included. The following tests were performed simultaneously during a single visit: IOP using DCT, GAT and PNT, OPA using DCT and CCT using ultrasound pachymetry. We studied the difference IOP between these 3 tonometers using Wilcoxon non-parametric test and the effect of CCT on IOP and OPA, as well as the relationship between OPA and IOP using Spearman correlation coefficient.The median PNT IOP was 24 mmHg (Inter-quartile range [IQR]: 22-26), median GAT IOP was 22 mmHg (IQR: 22-24), and median DCT IOP was 28.2 mmHg (IQR: 24.1-30.7). PNT and DCT had higher IOP values than GAT (median 2 mmHg and 6.2 mmHg, respectively). Mean CCT was 594.5 μm (SD 30.0). GAT IOP and DCT IOP showed an increase with increased corneal thickness (r:0.209; P=.036 and r:0.195; P=.051, respectively). PNT IOP did not change with CCT (r:0.15; P=.12). The median OPA was 4.8 mmHg (IQR: 3.6-6.1), and significantly increased with GAT IOP (r:0,38; P<.001) and with CCT (r:0.287; P=.004). This association was unclear with IOP PNT and IOP DCT (r:0.067; P=.50 and r:0,17, P=.08, respectively).DCT and PNT IOP values were higher than GAT IOP measurements in ocular hypertension patients. GAT IOP showed a significant increase with increased corneal thickness. Increased OPA seems to correlate with increased CCT and IOP, particularly if GAT is used.
Adult, Aged, 80 and over, Male, Corneal Pachymetry, Reproducibility of Results, Middle Aged, Cornea, Tonometry, Ocular, Humans, Female, Ocular Hypertension, Intraocular Pressure, Aged, Ultrasonography
Adult, Aged, 80 and over, Male, Corneal Pachymetry, Reproducibility of Results, Middle Aged, Cornea, Tonometry, Ocular, Humans, Female, Ocular Hypertension, Intraocular Pressure, Aged, Ultrasonography
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 3 | |
popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |