ATS Medical, Inc, developed a mechanical heart valve that has been in use since 1992. In this article, we present the results of 15 years of follow-up of patients who have undergone ATS heart valve replacement at our hospital.We performed ATS heart valve replacements on 231 patients between September 1993 and March 2008. Our operative mortality rate for the study period was 2.2%. The survival for postoperative thromboembolic events was 0.29%/pt-y for aortic valve replacement, 0.48%/pt-y for mitral, 0.80%/pt-y for double valve replacement, and overall 0.44%/pt-y. The survival after bleeding events was 0.29%/pt-y for aortic valve replacement, 0.16%/pt-y for mitral, 0%/pt-y for double valve replacement, and overall 0.19%/pt-y. Patient-prosthesis mismatch, as determined by echocardiography, was found in 83.3% of patients at 19 mm, but other sizes showed good valve function. Prosthetic valve noise was undetectable in 92.8% of patients, and quality of life was excellent.Few prosthetic valve-related complications were seen with ATS heart valve replacements in this study, and the follow-up results were favorable. The international normalized ratio was maintained in the range 1.6 to 2.0 in patients with aortic valve replacement in sinus rhythm. Not only bleeding events, seen at a rate of 0.19%/pt-y, but also thromboembolic events, at 0.44%/pt-y, were low when compared with conventional mechanical valves. Prosthetic valve noise is low, and this appears to be an excellent mechanical valve from the quality of life standpoint. The ATS valve has an excellent safety profile when compared with other mechanical valves.
Pulmonary and Respiratory Medicine, Male, Time Factors, Middle Aged, Aortic Valve, Heart Valve Prosthesis, Humans, Mitral Valve, Surgery, Female, Cardiology and Cardiovascular Medicine, Follow-Up Studies
Pulmonary and Respiratory Medicine, Male, Time Factors, Middle Aged, Aortic Valve, Heart Valve Prosthesis, Humans, Mitral Valve, Surgery, Female, Cardiology and Cardiovascular Medicine, Follow-Up Studies
| citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 33 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |