Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Journal of Surgical ...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Journal of Surgical Research
Article . 2018 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Robotic port-site hernias after general surgical procedures

Authors: Ramon Diez-Barroso; Carlos H. Palacio; Julian A. Martinez; Konstantinos Makris; Nader N. Massarweh; Christy Y. Chai; Samir S. Awad; +1 Authors

Robotic port-site hernias after general surgical procedures

Abstract

With the increasing use of the robotic platform in general surgery, whether 8-mm ports should be closed comes into question. We sought to characterize the incidence of port-site hernias (PSHs) among patients undergoing robotic-assisted general surgery.A retrospective chart review of a single institutional database identified patients who underwent robotic-assisted general surgery from July 2010 to December 2016. For each patient, the number, type, location, and size of all ports were collected. Twelve-millimeter port sites were routinely closed, whereas 5-mm and 8-mm port sites were not. PSH was detected on review of documented physical examination and of postoperative cross-sectional imaging, when available, in which case it was defined as a disruption of the fascia with or without eventration of tissue at a site of prior port placement.One hundred and seventy-eight patients underwent robotic-assisted general surgery, with 725 total ports: 433 8-mm working ports, 72 12-mm working ports, 178 12-mm camera ports, and 42 5-mm assistant ports. Ninety-four percent of the patients were men, the mean age was 63 ± 12, body mass index was 29 ± 7 kg/m2, and the median American Society of Anesthesiologists score was 3. Types of cases included 68 rectal (38.2%), 36 colon (20.2%), 25 hepatopancreatobiliary (14.0%), 21 inguinal hernia (11.8%), and 28 "other" (15.7%) operations. At a median follow-up of 193 d, there were three PSHs through 8-mm port sites (0.7%), two PSHs through 12-mm port sites (0.8%), and no PSH through 5-mm port sites. Two of the three 8-mm PSHs occurred in the early postoperative period and required emergent repair due to small bowel incarceration.PSHs through 8-mm robotic port sites occur infrequently but can cause significant morbidity. Further investigation with longer follow-up is warranted to better understand the true incidence of robotic PSH.

Related Organizations
Keywords

Male, Incidence, Middle Aged, Hernia, Abdominal, Postoperative Complications, Robotic Surgical Procedures, Humans, Female, Laparoscopy, Fascia, Aged, Retrospective Studies

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    72
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 1%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 1%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
72
Top 1%
Top 10%
Top 1%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!