
pmid: 27017568
Bacopaside I (BP-I) is the major pseudojujubogenin glycoside of Bacopa monniera (BM) extract which has been widely used as a nerve tonic to improve the memory and intellect of human beings from ancient times. A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of BP-I in mouse plasma and brain homogenate has been developed and validated. All biosamples were processed by liquid-liquid extraction and chromatographed on C18- reversed phase column using mobile phase consisting of ammonium acetate (10mM, pH 4) - acetonitrile (10:90, v/v) at a flow rate of 0.5mL/min. The detection was performed in negative electrospray ionization mode and the precursor/product ion transitions of BP-I and internal standard (IS) hydrochlorothiazide were quantified in multiple reaction monitoring (MRM) using QTRAP-5500 MS/MS. The linearity was established over the concentration range of 0.5-2000ng/mL (r(2)>0.990), with lower limit of quantification (LLOQ) of 0.5ng/mL in both plasma and brain matrix. Within- and between-run precision and accuracy were well within the acceptable limits of variation. Consistent and reproducible recovery (>70%) was obtained with insignificant matrix effect for BP-I and IS. The method fulfilled US Food and Drug Administration (USFDA) guidelines for bioanalytical method validation in terms of selectivity, sensitivity, linearity, accuracy, precision, matrix effect, dilution integrity, carry-over effect and stability. Further, the method was successfully applied to execute the plasma pharmacokinetics and brain distribution of BP-I in Swiss-albino mice following intravenous administration at a dose of 5mg/kg.
Male, Brain, Reproducibility of Results, Reference Standards, Saponins, Triterpenes, Mice, Limit of Detection, Tandem Mass Spectrometry, Animals, Chromatography, Liquid
Male, Brain, Reproducibility of Results, Reference Standards, Saponins, Triterpenes, Mice, Limit of Detection, Tandem Mass Spectrometry, Animals, Chromatography, Liquid
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 6 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
