image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Journal of Clinical ...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Journal of Clinical Densitometry
Article . 2006 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Cross Calibration of DXA as Part of an Equipment Replacement Program

Authors: Derek, Pearson; Barbara, Horton; Desmond J, Green;

Cross Calibration of DXA as Part of an Equipment Replacement Program

Abstract

The purpose of this study was to develop cross calibrations when replacing three dual-energy X-ray absorptiometers (GE Lunar DPXL [Madison, WI], DPXL, GE Lunar Expert [Madison, WI], Expert, Hologic QDR2000 [Waltham, MA]) with two new GE Lunar Prodigy instruments. Subjects previously scanned on the Expert or QDR2000 were transferred to Prodigy 1 and those previously scanned on the DPXL to Prodigy 2. A cohort of subjects was recalled for each old instrument, and approximately 20 subjects had lumbar spine and hip scans on each old instrument and the appropriate new instrument. An in vitro calibration was carried out using a Bona Fide Phantom (Bio-Imaging Technologies, Inc., Newtown, PA). Calibrations were fitted using a standardized principal components method. A Bland and Altman plot was used to calculate the mean difference and limits of agreement between instruments. Standardized bone mineral density (BMD) was also used to calibrate the Hologic to Prodigy 1. There was good agreement between instruments from the same manufacturer. As expected, BMD measured on the Prodigy was about 15% higher than the Hologic. Using standardized BMD to cross calibrate gave a mean difference of 3% at the lumbar spine. The limits of agreement following calibration are clinically significant, so it is not possible to apply a calibration to an individual subject for trending purposes, as the error is similar to the expected annual change in BMD, but can be used for cross calibration in clinical trials. The in vivo calibration gave better agreement than using standardized BMD. The phantom calibration was close to the in vivo calibrations at the spine, but not in some hip regions. When introducing a new instrument, a new baseline BMD has to be obtained for each subject.

Related Organizations
Keywords

Cohort Studies, Absorptiometry, Photon, Bone Density, Phantoms, Imaging, Humans, Osteoporosis, Reference Standards, United Kingdom

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    19
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
19
Average
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!