
AbstractBackgroundPercutaneous transcatheter radiofrequency ablation of atrial fibrillation with remote controlled magnetic navigation (RMN) has been shown to reduce radiation exposure to patients and physicians compared with conventional manual (MAN) ablation techniques.MethodsCatheter ablation for atrial fibrillation was performed utilizing RMN in 214 consecutive patients and MAN ablation techniques in 229 patients. We compared the fluoroscopy and procedural times between RMN and MAN catheter ablation of atrial fibrillation. Secondary objectives included comparing acute procedural success and short‐term complication rates between both ablation strategies.ResultsFluoroscopy time was significantly shorter in the RMN group than the MAN group (53.5±30.1 vs 68.1±27.6 min, respectively; p<0.01); however, the total procedural time was longer in the RMN group (280.2±74.4 min vs 213.1±64.75, respectively; p>0.001). Further subgroup analysis of the most recent 50 ablations each from the RMN and MAN groups, to attenuate the RMN learning curve effect, showed an even greater difference in fluoroscopy time (RMN vs MAN: 53.5±30.1 vs 68.1±27.6 min), though a consistently longer procedure time with RMN (249.5±65.5 vs 186.3±65.6 min, respectively). The acute procedural success rate was comparable between the groups (98.6% vs 95.6%, respectively; p=0.07). The rates of acute complications were similar in both groups (2.3% vs 4.8%, respectively; p=0.16).ConclusionsIn radiofrequency ablation of atrial fibrillation, RMN appears to significantly reduce fluoroscopy time compared with conventional MAN ablation, though at a cost of increased total procedural time, with comparable acute success rates and safety profile. A reduction in procedure and fluoroscopy times is possible with gaining experience.
Remote magnetic navigation, RC666-701, Diseases of the circulatory (Cardiovascular) system, Original Article, Atrial fibrillation
Remote magnetic navigation, RC666-701, Diseases of the circulatory (Cardiovascular) system, Original Article, Atrial fibrillation
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 9 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
