Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao International Journa...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
International Journal of Radiation Oncology*Biology*Physics
Article . 2005 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Intensity-modulated radiotherapy for lymphoma involving the mediastinum

Authors: Karyn A, Goodman; Sean, Toner; Margie, Hunt; Elisa J, Wu; Joachim, Yahalom;

Intensity-modulated radiotherapy for lymphoma involving the mediastinum

Abstract

To determine the feasibility, potential advantage, and indications for intensity-modulated radiotherapy (IMRT) in the treatment of Hodgkin's lymphoma or non-Hodgkin's lymphoma involving excessively large mediastinal disease volumes or requiring repeat RT.Sixteen patients with Hodgkin's lymphoma (n = 11) or non-Hodgkin's lymphoma (n = 5) undergoing primary radiotherapy or repeat RT delivered via an IMRT plan were studied. The indications for using an IMRT plan were previous mediastinal RT (n = 5) or extremely large mediastinal treatment volumes (n = 11). For each patient, IMRT, conventional parallel-opposed (AP-PA), and three-dimensional conformal (3D-CRT) plans were designed using 6-MV X-rays to deliver doses ranging from 18 to 45 Gy (median, 36 Gy). The plans were compared with regard to dose-volume parameters. The IMRT/AP-PA and IMRT/3D-CRT ratios were calculated for each parameter.For all patients, the mean lung dose was reduced using IMRT, on average, by 12% compared with AP-PA and 14% compared with 3D-CRT. The planning target volume coverage was also improved using IMRT compared with AP-PA but was not different from the planning target volume coverage obtained with 3D-CRT.In selected patients with Hodgkin's lymphoma and non-Hodgkin's lymphoma involving the mediastinum, IMRT provides improved planning target volume coverage and reduces pulmonary toxicity parameters. It is feasible for RT of large treatment volumes and allows repeat RT of relapsed disease without exceeding cord tolerance. Additional follow-up is necessary to determine whether improvements in dose delivery affect long-term morbidity and disease control.

Related Organizations
Keywords

Adult, Male, Lymphoma, Non-Hodgkin, Middle Aged, Radiation Dosage, Hodgkin Disease, Mediastinal Neoplasms, Feasibility Studies, Humans, Female, Radiotherapy, Conformal, Lung

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    94
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
94
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!