
Abstract A spatial steel frame with concrete slab and special-shaped multi-partition concrete filled steel tubular columns was tested in a simulated scenario of progressive collapse. The load-deformation relationship of the frame with damaged middle column under vertical load is discussed. Parametric analysis is also conducted by using a validated FE model. The results show that the failure of the specimen resulted from the fracture of the bottom beam flange eventually. The configuration of side plate connection and multi-partition concrete filled steel tubular column both could provide a reliable load-redistribution path for additional loads due to single column loss. The designed frame exerts good robustness to resist the collapse resulting from middle column loss. The simulation shows that single-column removal would cause additional lateral force and moment on the adjacent columns, besides axial force. The length of side plate exhibits more influence on the performance of the frame than the thickness of side plate.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 19 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
