Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ The University of Ma...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Engineering Structures
Article . 2019 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 6 versions
addClaim

Performance evaluation of demountable shear connectors with collar step at ambient and elevated temperatures

Authors: Sencu, R.m.; Wang, Y.c.; Yang, J.; Lam, D.;

Performance evaluation of demountable shear connectors with collar step at ambient and elevated temperatures

Abstract

This paper presents the results of an experimental programme to investigate the performance of a new composite shear connector that can be used to build deconstructable composite floors. A total of 21 push-out tests were conducted to quantify the effects of different design parameters, including different nominal temperature levels (20 °C, 100 °C, 300 °C, 450 °C, 600 °C), with the steel decking perpendicular and parallel to the steel section, two different embedded shear stud lengths and two different grades of concrete (C40/50 and C20/25). The tests were mainly carried out under steady-state condition where the specimen temperatures were increased to the desired target and the load was then applied until failure of the specimen. A few transient tests were also carried out, in which a load equal to the load carrying capacity of the steady-state test at 600 °C was applied, followed by increasing the specimen temperature until failure. Three modes were observed: (i) concrete crushing with stud fracture, (ii) stud fracture and (iii) concrete pull-out. Concrete pull-out occurred only on one specimen with concrete grade C20/25. It is found that the main failure mode at elevated temperatures not exceeding 400 °C was initiated by concrete crushing, concomitantly producing ductile stud damages. At elevated temperatures above 400 °C, the failure mode changed to shear stud fracture. The Eurocode 4 calculation equations were shown to produce shear connector resistances to be in reasonable agreement with the steady state results for the higher-grade concrete, even though the previous equations were developed for welded shear studs. The transient state tests failed at lower temperatures than the target temperature of 600 °C, indicating it may not be safe to use steady state tests for evaluation of shear connector resistance at high temperatures.

Country
United Kingdom
Related Organizations
Keywords

Demountable shear connectors; deconstructable steel structures; floor systems; push-out test; load-slip; elevated temperature; composite beam design.

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    16
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
16
Top 10%
Top 10%
Top 10%
Green