Abstract In this paper, the overstrength, ductility and response modification factors of moment resistant frame (MRF) with steel vertical slit panel (SSP-MRF) were investigated and determined. For this purpose, buildings with various stories were used. Abaqus software was used to perform the static pushover analysis, linear dynamic analysis, and nonlinear incremental dynamic analysis. In this research, seismic response modification factor has been evaluated for each model structure using pushover analysis, and the tentative value 8.11 has been proposed for the ultimate limit state design method. Some of the results of pushover analysis and nonlinear incremental dynamic analyses were compared. According to this comparison, the response modification factor of 10-story model structure derived from pushover analysis (6.14) was slightly smaller than those obtained from incremental dynamic analyses (7.5).
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 24 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |