Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Journal of the Ameri...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Journal of the American Society of Echocardiography
Article . 2025 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Calculation of Regurgitant Volume Using Echocardiographic Volumetric Method for Accurate Diagnosis of Severe Mitral Regurgitation

Authors: Ga Yun Kim; Ha Hye Jo; So-Min Lim; Dayoung Pack; Hye Soo Lee; Jong En Lee; Hyun Jung Koo; +7 Authors

Calculation of Regurgitant Volume Using Echocardiographic Volumetric Method for Accurate Diagnosis of Severe Mitral Regurgitation

Abstract

Recent studies have shown suboptimal results of the proximal isovelocity surface area (PISA) method and the American Society of Echocardiography (ASE) algorithm for diagnosing severe primary mitral regurgitation (MR). The aim of this study was to evaluate the accuracy of regurgitant volume (RegVol) calculated using volumetric transthoracic echocardiography (TTE) for diagnosing severe primary MR.A total of 74 patients with primary MR due to prolapse or flail leaflet were prospectively recruited for both TTE and cardiac magnetic resonance (CMR) imaging. RegVol was calculated using PISA (RegVol_PISA) or the volumetric method (left ventricular total stroke volume - systolic forward outflow volume; RegVol_TTE). According to the ASE algorithm, patients with four or more parameters were diagnosed with severe MR. RegVol_CMR ≥ 60 mL was used as the gold standard for diagnosing severe MR.All subjects had at least moderate to severe MR according to ASE guidelines. CMR imaging confirmed that 30 patients (41%) had severe MR. The concordance correlation coefficient between RegVol_TTE and RegVol_CMR (0.809; 95% CI, 0.715-0.893) was higher than that between RegVol_PISA and RegVol_CMR (0.468; 95% CI, 0.323-0.576). The overall accuracy of RegVol_TTE for the diagnosis of severe MR was 90.5% (95% CI, 81.5-96.1), which was significantly higher than that of RegVol_PISA (64.9%; 95% CI, 52.9-75.6; P < .001) and the ASE algorithm (77.0%; 95% CI, 65.8-86.0; P = .004). The area under the curve for RegVol_TTE (0.95; 95% CI, 0.90-1.00) was significantly larger than that for RegVol_PISA (0.88; 95% CI, 0.80-0.96; P = .028).RegVol_TTE showed better diagnostic performance than the PISA method and the ASE algorithm in diagnosing severe MR. Further investigations are necessary to evaluate the clinical usefulness of the routine use of RegVol_TTE.

Related Organizations
Keywords

Male, Echocardiography, Three-Dimensional, Mitral Valve Insufficiency, Reproducibility of Results, Stroke Volume, Middle Aged, Severity of Illness Index, Sensitivity and Specificity, Echocardiography, Humans, Mitral Valve, Female, Prospective Studies, Algorithms, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    5
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
5
Top 10%
Average
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!