Abstract In this Technical Note, we describe a method of mini‐open long head biceps subpectoral tenodesis. The implant used is a threadless expanding PEEK (polyether ether ketone) interference device that fixes the biceps tendon in a drill hole in the humerus under the inferior border of the pectoralis major tendon. The diameter of the drill hole varies between 6 and 8 mm depending on the width of the tendon. The procedure can be performed through a 3‐cm incision centered on the inferior border of the pectoralis tendon. Based on our experience, it is a quick, safe, and reliable tenodesis procedure.
Orthopedic surgery, Technical Note, RD701-811
Orthopedic surgery, Technical Note, RD701-811
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |