Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Clinical Neurophysio...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Clinical Neurophysiology
Article . 2012 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Feasibility of ocular vestibular-evoked myogenic potentials (oVEMPs) recorded with eyes closed

Authors: Yen-Chieh, Huang; Tsung-Lin, Yang; Yi-Ho, Young;

Feasibility of ocular vestibular-evoked myogenic potentials (oVEMPs) recorded with eyes closed

Abstract

This study compared the characteristic parameters of ocular vestibular-evoked myogenic potential (oVEMP) test between eyes gazing up and eyes closed to evaluate the feasibility of oVEMP test with eyes closed.Twenty-three healthy adults underwent oVEMP testing with upward gaze and with eyes closed in a randomized order. For each condition, the thickness of the inferior oblique and inferior rectus muscles, and the distance from the electrode on the skin to each muscle were measured via ultrasonography. Two patients with pathological ears were also included in this study for comparison.Twenty of the 23 subjects showed clear oVEMPs regardless of whether eyes were gazing up or eyes were closed. Mean latencies of nI and pI, and nI-pI interval with eyes closed were significantly prolonged when compared with those measured with eyes up. The mean nI-pI amplitude with eyes closed was significantly smaller than that with eyes up. However, no significant difference existed in the mean asymmetry ratio of amplitude between the two conditions. With eyes closed, the mean distances from the skin to the inferior oblique and inferior rectus muscles are 0.17±0.03 and 0.40±0.09 cm, respectively. In contrast with eyes gazing up, the mean distance from the skin to the inferior rectus muscle reduces significantly to 0.23±0.09 cm, whereas the inferior oblique muscle slips out of ultrasonographic view.Ocular VEMP can also be recorded with eyes closed in those who cannot perform upward gaze. However, the characteristic parameters of oVEMP are different between the eyes up and eyes closed conditions, probably because various extraocular muscles are involved in the generation of oVEMPs.In those who cannot gaze upward such as small children, oVEMPs can be recorded by eyes closed.

Keywords

Adult, Male, Young Adult, Oculomotor Muscles, Feasibility Studies, Humans, Female, Middle Aged, Vestibular Evoked Myogenic Potentials, Vision, Ocular

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    17
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
17
Average
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!