
pmid: 32735941
To analyze the topographic matching of oblong osteochondral allografts to treat large oval medial femoral condyle (MFC) lesions using computer simulation models. The secondary objective was to determine whether lateral femoral condyle (LFC) grafts would have a similar surface matching when compared with MFC grafts in this setting.Human femoral hemicondyles (10 MFCs, 7 LFCs) underwent 3-dimensional computed tomography. Models were created from computed tomography images and exported into point-cloud models. Donor-recipient matches with large condylar width mismatch were excluded. The remaining specimen were divided into 3 donor-recipient groups with 2 defect sizes (17 × 30 mm and 20 × 30 mm): 20 MFC donor (MFCd)-MFC recipient (MFCr), 27 ipsilateral LFC donor (LFCd)-MFCr, and 26 contralateral LFCd-MFCr. Grafts were optimally virtually aligned with the MFCr defect. Mismatch of the articular cartilage and subchondral bone surfaces between the graft and the defect and articular step-off were calculated.MFCd grafts resulted in articular cartilage surface mismatch and peripheral step of less than 0.5 mm for both defect sizes. The subchondral bone surface mismatch was significantly greater than the articular cartilage surface mismatch (P < .01) in both defect sizes). Conversely, the ipsilateral and contralateral LFCd grafts resulted in significantly greater articular cartilage surface mismatch and step-off for both defect sizes when compared to MFCd grafts (P < .01).Oblong MFC allografts provide acceptable topographic matching for large oval MFC lesions when condylar width differences are minimized. However, concern exists in using oblong LFC allografts for MFC defects, as this can result in increased peripheral step-off and surface mismatch.These data reinforce the ability to use oblong MFC osteochondral allograft for treating oval cartilage lesions of the MFC when condylar width is considered. Although other studies have demonstrated LFCs can be used to treat circular defects on the MFC, this may not be true for oblong grafts.
Cartilage, Articular, Bone Transplantation, Intra-Articular Fractures, Knee Joint, Imaging, Three-Dimensional, Cadaver, Humans, Transplantation, Homologous, Computer Simulation, Femur, Tomography, X-Ray Computed, Epiphyses
Cartilage, Articular, Bone Transplantation, Intra-Articular Fractures, Knee Joint, Imaging, Three-Dimensional, Cadaver, Humans, Transplantation, Homologous, Computer Simulation, Femur, Tomography, X-Ray Computed, Epiphyses
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 9 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
