<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://www.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=undefined&type=result"></script>');
-->
</script>
pmid: 30248586
The aim of the present work is to determine dosimetric characteristics of commercial optically stimulated luminescence dosimeter (OSLD) to estimate equivalent dose in the patient undergoing panoramic radiography procedure. Digital panoramic unit "Instrumentarium OP200D" was used. OSL dosimeters were optically bleached before any exposure procedure. InLight™ OSL nanodosimeters were placed on the thyroid surface between the head and neck. The exposure parameters for all measurements was standard value consisted in 66 kV, 5 mA, and 14.1 s. Standard size field of view (FOV) scanning mode was used. Dosimeters were calibrated for the air kerma. Reported male adult equivalent doses from 21 to 45 µSv for each scanning for standard size field of view (FOV). Meanwhile reported female adult equivalent doses from 28 to 75 µSv for standard size field of view (FOV) considering all heights. The lowest equivalent dose (21 μSv) was observed in the male thyroid gland surface (S) position for medium height. The highest equivalent dose (75 μSv) was for female small height in the right parotid surface (R) position. In conclusion, the results demonstrate that OSL dosimeters are appropriate in vivo dosimetry system for dental panoramic dose measurements.
Adult, Male, Phantoms, Imaging, Radiation Dosimeters, Thyroid Gland, Reproducibility of Results, Radiation Dosage, Optically Stimulated Luminescence Dosimetry, Calibration, Radiography, Panoramic, Humans, Parotid Gland, Female
Adult, Male, Phantoms, Imaging, Radiation Dosimeters, Thyroid Gland, Reproducibility of Results, Radiation Dosage, Optically Stimulated Luminescence Dosimetry, Calibration, Radiography, Panoramic, Humans, Parotid Gland, Female
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 3 | |
popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |