AbstractThe paper presents the calculated dose rate carried out by using MicroShield code to show the importance of hot water layer system (HWL) in 22MW open pool type reactor from the radiation protection safety point of view. The paper presents the dose rate profiles over the pool surface in normal and abnormal operations of HWL system. The results show that, in case of losing the hot water layer effect, the radiation dose rate profiles over the pool surface will increase from values lower than the worker permissible dose limits to values very higher than the permissible dose limits.
Radioprotection, Open pool research reactor, Radiation dose calculation, TA1-2040, Engineering (General). Civil engineering (General), Radiological hazard, Engineering(all)
Radioprotection, Open pool research reactor, Radiation dose calculation, TA1-2040, Engineering (General). Civil engineering (General), Radiological hazard, Engineering(all)
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 15 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |