doi: 10.1007/bf02697320
pmid: 17914199
The corneal biomechanical properties following descemetorhexis with endokeratoplasty (DXEK) and in normal subjects were studied in 100 eyes (12 DXEK and 88 age-matched normal subjects). Corneal hysteresis measurements were significantly lower in DXEK vs normal subjects. DXEK has a direct effect on corneal hysteresis and corneal biomechanical properties of the human cornea.
Aged, 80 and over, Male, Diagnostic Techniques, Ophthalmological, Middle Aged, Biomechanical Phenomena, Corneal Diseases, Cornea, Corneal Transplantation, Humans, Female, Descemet Membrane, Aged
Aged, 80 and over, Male, Diagnostic Techniques, Ophthalmological, Middle Aged, Biomechanical Phenomena, Corneal Diseases, Cornea, Corneal Transplantation, Humans, Female, Descemet Membrane, Aged
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 14 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |