image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Medical & Biological...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Medical & Biological Engineering & Computing
Article . 1997 . Peer-reviewed
License: Springer TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Two-point calibration procedure of the forced oscillation technique

Authors: K N, Desager; M, Cauberghs; K P, Van de Woestijne;

Two-point calibration procedure of the forced oscillation technique

Abstract

The forced oscillation technique is usually calibrated by loading the measuring device with a known impedance. A correction function is calculated, relating the measured and reference impedances at each frequency. However, this one point calibration procedure does not account for transducer asymmetry. A procedure has previously been presented to circumvent this problem: in addition to one known reference impedance, the calibration was repeated with the system occluded (infinite impedance). The aim of the present study was to evaluate a variant of this procedure, in which instead of resorting to an extreme condition imposing high requirements on the flow measuring system, two reference loads of 4 and 50 hPal-1 s were measured, thus covering the range of impedances observed in children and infants (a two-point procedure). The calibration procedure was performed with these two impedances and evaluated with a third impedance of approximately 17 hPal-1 s. The results of three calibration procedures were compared: one-point, two-point and a previously reported calibration procedure. Impedances consisted of sintered glass and mesh wire screens mounted in glass or polyvinyl tubes. For low impedance values, in the range of 4 to 17 hPal-1 s, measured and predicted values were similar for the three calibration procedures at frequencies from 4-52 Hz, although with the one point calibration procedure there was some underestimation above 44 Hz. With the highest load, especially above 32 Hz, marked discrepancies between measured and predicted values were observed with the one-point calibration procedure and the previously reported calibration procedure. Under these circumstances the two-point procedure is preferred.

Related Organizations
Keywords

Calibration, Respiratory Mechanics, Transducers, Pressure, Humans, Respiratory Function Tests

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    5
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
5
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!