image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Medical & Biological...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Medical & Biological Engineering & Computing
Article . 1983 . Peer-reviewed
License: Springer TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Errors in four-electrode impedance plethysmography

Authors: D K, Swanson; J G, Webster;

Errors in four-electrode impedance plethysmography

Abstract

The errors in electrical impedance plethysmography are not well known. In the paper errors due to inadequate instrumentation, improper electrode application, and physiological changes have been analysed. Minimum electrical requirements for a general purpose four-electrode instrument are: (a) input impedance of voltage-sensing circuit+4 kΩ; (b) output impedance of constant-current source+20 kΩ; (c) c.m.r.r.+400; (d) common-mode input impedance+40 kΩ; and (e) apparent change of resistance due to noise×0·5 mΩ. All electrodes should be separated by at least one limb diameter. Changes of electrode impedance due to pressure produce negligible error in a four-electrode configuration. The only way to eliminate the large subject-motion errors is to eliminate the motion. Changes of blood resistivity with velocity produce an error estimated at 10 per cent. A repeatability test on the upper arm gave a standard deviation of 6 per cent of the mean.

Keywords

Electric Conductivity, Humans, Equipment Failure, Plethysmography, Impedance, Electrodes, Mathematics, Electronics, Medical

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    33
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
33
Top 10%
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!