</script>doi: 10.1007/bf02441305
pmid: 7321610
11 New Zealand white rabbits with 45 degree midshaft oblique osteotomies were stressed in shear while monitoring acoustic emission events. The ringdown counting method demonstrated a reasonably reproducible pattern when counting events against load; that is, each fracture remained essentially quiet until over 50% of load to failure had been applied. The rate of events to load increased sharply just before and during failure. This technique has clinical possibilities.
Tibial Fractures, Wound Healing, Sound Spectrography, Freezing, Animals, Rabbits, Bony Callus
Tibial Fractures, Wound Healing, Sound Spectrography, Freezing, Animals, Rabbits, Bony Callus
| citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 18 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |