doi: 10.1007/bf01913064
The dynamic DSC/DTA method was observed to give better selectivity and reproducibility than the isothermal method when estimating relative oxidation stability of plastics materials. The dynamic DSC/DTA method is in this survey exposed to a round robin test. Results of various instruments and test stations are compared, and their compatibility is unexpectedly good. Subsequently the dynamic DSC/DTA method was chosen as the quality control method and will be published as Finnish standard SFS 3449.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 8 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |