Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Heart and Vesselsarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Heart and Vessels
Article . 1996 . Peer-reviewed
License: Springer TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Movement of pulmonary artery catheters

Authors: M S, Chew; E, Sloth; M, Veien; K V, Jensen; H H, Kure; J M, Hasenkam;

Movement of pulmonary artery catheters

Abstract

Intraluminal movements of pulmonary artery catheters are seldom considered, although they may have a significant impact on flow measurement and safety. The purpose of this study was to document the movements of these catheters within the heart cycle, and to establish whether any patterns existed. We analyzed two-dimensional real time echocardiography cross-sectional images of the human pulmonary artery in 20 patients, plotting the position of the intra-arterial catheter frame-by-frame onto a standardized template. We found that movement of the catheter within the pulmonary artery occurred in a seemingly random pattern. There was no movement pattern to the inferior right of the vessel, an area known to have complex velocity profiles and erroneous velocity measurements. The catheter moved substantially throughout the heart cycle, occasionally quite close to the vessel wall. We observed significant movement of the pulmonary artery catheter throughout the heart cycle, without any predictable pattern. Although we did not specifically investigate the effect of these movements on cardiac output, they imply that intra-arterial Doppler flow measurements from the pulmonary artery may be inaccurate, since a stable catheter position, and hence, a sample volume, cannot be ensured. Further speculation can be made on the implications of these movements in regard to thermodilution cardiac output and safety.

Related Organizations
Keywords

Adult, Motion, Equipment Safety, Echocardiography, Catheterization, Swan-Ganz, Humans, Cardiac Output, Middle Aged, Pulmonary Artery, Rheology, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    4
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
4
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!