image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Intensive Care Medic...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Intensive Care Medicine
Article . 1992 . Peer-reviewed
License: Springer TDM
Data sources: Crossref
Survey of Anesthesiology
Article . 1992 . Peer-reviewed
Data sources: Crossref
versions View all 3 versions
addClaim

Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients

Authors: C, Martin; J P, Auffray; C, Badetti; G, Perrin; L, Papazian; F, Gouin;

Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients

Abstract

Continuous monitoring of mixed venous (SvO2) and central venous (ScO2) oxygen saturation was compared in 7 critically-ill patients (Apache II score: 19 +/- 2.1) to determine whether or not information derived from ScO2 were reliable in clinical practice. Patients were catheterized with both a pulmonary artery (PA) and a central venous (CV) catheter, each of them mounted with fiberoptic sensors (Opticath PA Catheter P7110 and Opticath CV Catheter U440, Abbott). A total of 580 comparative measurements were obtained during periods without and with therapeutic interventions (drug-titration, bronchial suction, use of PEEP, changes in FiO2 ...). The systematic error between the 2 measurement techniques was 0.6% and 0.3% in periods with and without therapeutic interventions, respectively. The variability between the 2 techniques was 10% for both periods. Differences between the values were greater than or equal to 5% in 49% of values during periods of stability and in 50% of values during periods with therapeutic interventions. There were poor correlations between the values during periods without (r = 0.48) and with therapeutic interventions (r = 0.62). Better, but still less than ideal, correlations were obtained with changes in SvO2 and ScO2 during periods without (r = 0.70) and with therapeutic interventions (r = 0.77). Although there is a need to develop a simple technique to monitor mixed venous oxygen saturation, the present study indicates that ScO2 monitoring was not reliable in the study patients.

Keywords

Adult, Male, Catheterization, Central Venous, Critical Illness, Reproducibility of Results, Middle Aged, Oxygen, Catheterization, Swan-Ganz, Humans, Regression Analysis, Female, Prospective Studies, Blood Gas Analysis, Aged, Monitoring, Physiologic

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    87
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 1%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
87
Top 10%
Top 1%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!