doi: 10.1007/bf01694771
pmid: 8366228
To compare the accuracy of PI/PImax ratio and other commonly used indices in predicting weaning outcome.A prospective study.Intensive care unit.31 stable intubated patients ready to undergo weaning trial.A simple method was developed to measure the PI and PImax in intubated patients. The accuracy of PI/PImax ratio and other commonly used indices in predicting outcome were compared. All indices were measured prior to weaning trial using standardized methods.Minute ventilation of the successful patients (13.00 +/- 0.67 (SE) l/min) was not significantly different from the failure patients (10.64 +/- 1.26 l/min, p = 0.10). The PI and PImax for the successful patients (11.48 +/- 1.25 cmH2O and 47.77 +/- 4.48 cmH2O, respectively) and the unsuccessful patients (14.32 +/- 2.31 cmH2O and 40.16 +/- 4.55 cmH2O, respectively) were also not significantly different (p = 0.28 and 0.24, respectively). The PI/PImax ratio was lower for the weaning successes (0.26 +/- 0.03) than for the weaning failures (0.36 +/- 0.04, p < 0.05). The threshold value of 0.3 for PI/PImax provided the best separation between weaning success and failure patients. The combined usage of rapid shallow breathing index and PI/PImax ratio provided the highest accuracy with sensitivity of 0.81 and specificity of 0.93.The PI/PImax ratio provided a good separation between the patients who were successfully weaned and those who failed. It provides additional discriminative power to f/VT.
Heart Failure, Male, Respiratory Distress Syndrome, Neuromuscular Diseases, Pneumonia, Middle Aged, Prognosis, Airway Obstruction, Intensive Care Units, Inhalation, Humans, Female, Lung Volume Measurements, Pulmonary Ventilation, Ventilator Weaning, Inspiratory Capacity, Aged
Heart Failure, Male, Respiratory Distress Syndrome, Neuromuscular Diseases, Pneumonia, Middle Aged, Prognosis, Airway Obstruction, Intensive Care Units, Inhalation, Humans, Female, Lung Volume Measurements, Pulmonary Ventilation, Ventilator Weaning, Inspiratory Capacity, Aged
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 48 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |