doi: 10.1007/bf01574838
In designing electromagnetic circuits the pole surface leakage flux introduced by an air-gap, must be known. After defining the so called “utilization factor”, a review of the existing formulas for calculating it, is given. The major part of the paper deals with the presentation of a new and very accurate formula, based on the method of conformal mapping. Finally this formula is compared with experimental results.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |