doi: 10.1007/bf00192133
The psychrometric apparatus design for Bowen ratio determination reported previously by Sargeant and Tanner was modified and a new apparatus built. Modification of the intake design improved the symmetry and rigidity of the sensor mounting. Wet- and dry-bulb differences were measured with an error less than 0.01 °C over a vertical distance of 1 m. Continuous measurements of the Bowen ratio over a 7.8-m Douglas fir forest were made for 6 weeks. An example of the energy balance for the forest for one day using this equipment is reported.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 52 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 1% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |