Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao European Radiologyarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
European Radiology
Article . 1996 . Peer-reviewed
License: Springer TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Arterial angiography in high-kilovoltage technique with gadolinium as the contrast agent: first clinical experience

Authors: F, Fobbe; F, Wacker; S, Wagner;

Arterial angiography in high-kilovoltage technique with gadolinium as the contrast agent: first clinical experience

Abstract

Iodine-containing contrast agents are currently used for angiography. However, due to the relatively low atomic number of iodine, imaging must be performed with a relatively low tube voltage. Gadolinium has been used for several years as a contrast agent in MRI with low adverse side effects. This substance has a higher atomic number as compared with iodine. We investigated whether the use of a gadolinium-containing contrast agent with a higher tube voltage reduces the radiation exposure in angiography, and how the image quality compares with the previous technique. A total of 15 patients were examined with either a survey angiography or a selective angiography. In all patients angiography was performed with an iodine-containing contrast agent with a tube voltage of 75 kV. Then gadolinium-containing contrast agent was administered immediately with a tube voltage of 110 kV. Radiation exposure and image quality were compared. On average, a dose reduction factor of 3.57 times was achieved by using 110 instead of 75 kV. However, the image quality was poorer in the majority of cases as compared with the images taken with iodine as a contrast agent and a tube voltage of 75 kV. The poorer image quality is caused by the relative low concentration (0.5 M) of the used gadolinium solution. A 1 M solution is currently tested for market approval and would probably solve this problem.

Related Organizations
Keywords

Aged, 80 and over, Gadolinium DTPA, Male, Angiography, Contrast Media, Gadolinium, Arteries, Middle Aged, Pentetic Acid, Radiation Dosage, Iopamidol, Pelvis, Portal System, Injections, Intravenous, Organometallic Compounds, Humans, Female, Aorta, Abdominal, Aged, Iodine

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    34
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
34
Average
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!