In this paper, a current controller for grid-connected inverter is proposed by using a fuzzy logic control algorithm. In PI controller to control the grid-connected inverter, the gains of PI controller are changed with the aid of the fuzzy logic algorithm in order to get the fast transient performance despite of the input variations and load disturbances. The inputs of fuzzy logic controller are the error between the measured currents and the reference values in rotating reference frame, and the derivation of regulated voltage. The effectiveness of proposed controller strategy has been verified by simulation with PSIM software and compared with that of the conventional PI controller.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 2 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |