AbstractObjectiveThe variability of nuchal translucency thickness (NT) measurements in the first trimester appears to be associated in part with caliper placement. Methods for obtaining semi‐automated adjusted measurements (SAAMs) can provide several NT values (maximum, minimum, mean and median) automatically within a manually set frame in the zone of interest. This study sought to assess the feasibility and reproducibility of these SAAM‐NTs.MethodsThree readers, two experts and one less experienced, examined archive images of 160 patients and obtained SAAM‐NTs from them, on two separate occasions. The intra‐ and interobserver reproducibility were assessed by calculating the intraclass correlation coefficients (ICCs) for maximum, mean and median SAAM‐NTs, and Bland–Altman plots were constructed.ResultsSAAM‐NTs were technically feasible for all 160 images. The range of ICCs for intraobserver reproducibility was 0.76–0.93 for mean SAAM‐NT, 0.76–0.95 for median SAAM‐NT and 0.74–0.95 for maximum SAAM‐NT. Interobserver ICCs were 0.85, 0.85 and 0.84 for mean SAAM‐NT, median SAAM‐NT and maximum SAAM‐NT, respectively. There were no significant differences for intra‐ and interobserver reproducibility of median, mean and maximum SAAM‐NTs.ConclusionsSAAM‐NT is feasible with a high level of intra‐ and interobserver reproducibility. This easy‐to‐use method has the potential to simplify screening during the first trimester. It should be evaluated further and compared with the manual measurement method. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Observer Variation, Pregnancy Trimester, First, Pregnancy, Practice Guidelines as Topic, Feasibility Studies, Humans, Reproducibility of Results, Female, Clinical Competence, Nuchal Translucency Measurement
Observer Variation, Pregnancy Trimester, First, Pregnancy, Practice Guidelines as Topic, Feasibility Studies, Humans, Reproducibility of Results, Female, Clinical Competence, Nuchal Translucency Measurement
| citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 16 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |