doi: 10.1002/nbm.1100
pmid: 17075960
AbstractThe background underpinning the clinical use of ultrashort echo time, SPRITE and other pulse sequences for imaging bone and other connective tissues with short T2 is reviewed. Features of the basic physics relevant to UTE imaging are described, including the consequences when the radiofrequency pulse duration is of the order of T2 so that rotation of tissue magnetization into the transverse plane is incomplete. Consequences of the broad linewidth of short T2 components are also discussed, including partial saturation by off‐resonance fat suppression pulses as well as those used in multislice and multiecho imaging. The need for rapid data acquisition of the order of T2 is explained. The basic two‐dimensional UTE pulse sequence with its half excitation pulse and radial imaging from the centre of k‐space is described, together with options that suppress fat and/or reduce the signal from long T2 components. The basic features of SPRITE and other sequences with very short TE are described. Image interpretation is discussed. Clinical features of the imaging of cortical bone, tendons, ligaments, menisci, periosteum and the spine are illustrated. The source of the short T2 signal in these tissues is predominantly collagen and water tightly bound to collagen. Short T2 components in all of these tissues are detectible and may show high signals. Possible future developments are outlined, as are technical limitations of clinical magnetic resonance systems. Copyright © 2006 John Wiley & Sons, Ltd.
Connective Tissue, Echo-Planar Imaging, Image Interpretation, Computer-Assisted, Animals, Humans, Signal Processing, Computer-Assisted, Image Enhancement, Bone and Bones
Connective Tissue, Echo-Planar Imaging, Image Interpretation, Computer-Assisted, Animals, Humans, Signal Processing, Computer-Assisted, Image Enhancement, Bone and Bones
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 194 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 1% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 1% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |