
PurposeHead motion is a significant problem in diffusion‐weighted imaging as it may cause signal attenuation due to residual dephasing during strong diffusion encoding gradients even in single‐shot acquisitions. Here, we present a new real‐time method to prevent motion‐induced signal loss in DWI of the brain.MethodsThe method requires a fast motion tracking system (optical in the current implementation). Two alterations were made to a standard diffusion‐weighted echo‐planar imaging sequence: first, real‐time motion correction ensures that slices are correctly aligned relative to the moving brain. Second, the tracking data are used to calculate the motion‐induced gradient moment imbalance which occurs during the diffusion encoding periods, and a brief gradient blip is inserted immediately prior to the signal readout to restore the gradient moment balance.ResultsPhantom experiments show that the direction as well as magnitude of the gradient moment imbalance affects the characteristics of unwanted signal attenuation. In human subjects, the addition of a moment‐restoring blip prevented signal loss and improved the reproducibility and reliability of diffusion tensor measures even in the presence of substantial head movements.ConclusionThe method presented can improve robustness for clinical routine scanning in populations that are prone to head movements, such as children and uncooperative adult patients. Magn Reson Med 71:2006–2013, 2014. © 2013 Wiley Periodicals, Inc.
Echo-Planar Imaging, Phantoms, Imaging, Reproducibility of Results, Signal Processing, Computer-Assisted, methods [Echo-Planar Imaging], Healthy Volunteers, Motion, Diffusion Magnetic Resonance Imaging, methods [Image Processing, Computer-Assisted], Head Movements, methods [Diffusion Magnetic Resonance Imaging], Image Processing, Computer-Assisted, Humans, ddc: ddc:610
Echo-Planar Imaging, Phantoms, Imaging, Reproducibility of Results, Signal Processing, Computer-Assisted, methods [Echo-Planar Imaging], Healthy Volunteers, Motion, Diffusion Magnetic Resonance Imaging, methods [Image Processing, Computer-Assisted], Head Movements, methods [Diffusion Magnetic Resonance Imaging], Image Processing, Computer-Assisted, Humans, ddc: ddc:610
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 27 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
