Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Magnetic Resonance i...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Magnetic Resonance in Medicine
Article . 2013 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
http://dx.doi.org/10.1002/mrm....
Article . 2013 . Peer-reviewed
Data sources: SNSF P3 Database
MPG.PuRe
Article . 2014
Data sources: MPG.PuRe
versions View all 5 versions
addClaim

Triple echo steady‐state (TESS) relaxometry

Authors: Heule Rahel; Ganter Carl; Bieri Oliver;

Triple echo steady‐state (TESS) relaxometry

Abstract

PurposeRapid imaging techniques have attracted increased interest for relaxometry, but none are perfect: they are prone to static (B0) and transmit (B1) field heterogeneities, and commonly biased by T2/T1. The purpose of this study is the development of a rapid T1 and T2 relaxometry method that is completely (T2) or partly (T1) bias‐free.MethodsA new method is introduced to simultaneously quantify T1 and T2 within one single scan based on a triple echo steady‐state (TESS) approach in combination with an iterative golden section search. TESS relaxometry is optimized and evaluated from simulations, in vitro studies, and in vivo experiments.ResultsIt is found that relaxometry with TESS is not biased by T2/T1, insensitive to B0 heterogeneities, and, surprisingly, that TESS‐T2 is not affected by B1 field errors. Consequently, excellent correspondence between TESS and reference spin echo data is observed for T2 in vitro at 1.5 T and in vivo at 3 T.ConclusionTESS offers rapid T1 and T2 quantification within one single scan, and in particular B1‐insensitive T2 estimation. As a result, the new proposed method is of high interest for fast and reliable high‐resolution T2 mapping, especially of the musculoskeletal system at high to ultra‐high fields. Magn Reson Med 71:230–237, 2014. © 2013 Wiley Periodicals, Inc.

Keywords

Imaging, Three-Dimensional, Knee Joint, Image Interpretation, Computer-Assisted, Humans, Reproducibility of Results, Image Enhancement, Magnetic Resonance Imaging, Sensitivity and Specificity, Algorithms

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    87
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
87
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!