doi: 10.1002/mrm.23184
pmid: 22006586
AbstractAn alternative to the standard echo‐planar spectroscopic imaging technique is presented, spectroscopic imaging using concentrically circular echo‐planar trajectories (SI‐CONCEPT). In contrast to the conventional chemical shift imaging data, the sampled data from each set of concentric rings were regridded into Cartesian space. Usage of concentric k‐space trajectories has the advantage of requiring significantly reduced slew rates than echo‐planar spectroscopic imaging, allowing for the collection of higher spectral bandwidths and opening the door for high‐bandwidth echo‐planar styled spectroscopic imaging at higher magnetic fields. Before two‐dimensional spatial and one‐dimensional spectral encoding, the volume of interest was localized using the standard point‐resolved spectroscopy sequence. The feasibility of using concentric k‐space trajectories is demonstrated, and the spatial profiles and representative spectra are compared with the standard echo‐planar spectroscopic imaging technique in a gray matter phantom containing metabolites at physiological concentrations and healthy human brain in vivo. The symmetric nature of the concentric circles also reduces the number of required excitations for a given resolution by a factor of two. Possible artifacts and limitations are discussed. Magn Reson Med, 2011. © 2011 Wiley Periodicals, Inc.
Adult, Male, Magnetic Resonance Spectroscopy, Echo-Planar Imaging, Phantoms, Imaging, Brain, Reproducibility of Results, Image Enhancement, Sensitivity and Specificity, Image Interpretation, Computer-Assisted, Humans, Algorithms
Adult, Male, Magnetic Resonance Spectroscopy, Echo-Planar Imaging, Phantoms, Imaging, Brain, Reproducibility of Results, Image Enhancement, Sensitivity and Specificity, Image Interpretation, Computer-Assisted, Humans, Algorithms
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 49 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |