Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Medical and Pediatri...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Medical and Pediatric Oncology
Article . 2002 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
versions View all 2 versions
addClaim

Comparison of manual and automated leukocyte counts for determination of the absolute neutrophil count: Application to a pediatric oncology clinic***

Authors: David M, Parham; Ruth, Ready; Kimo, Stine; Carolyn, Quiggins; David, Becton; Paula, North;

Comparison of manual and automated leukocyte counts for determination of the absolute neutrophil count: Application to a pediatric oncology clinic***

Abstract

AbstractBackgroundDetermination of the absolute neutrophil count (ANC) is a critical test prior to initiation of chemotherapy and is a standard component of cancer therapy protocols. Automated determination of this parameter potentially shortens the turnaround time necessary between specimen phlebotomy and chemotherapy infusion in an outpatient setting. However, there are certain factors that can lead to spuriously elevated or lowered ANCs, possibly leading to inappropriate dosage. We therefore compared ANC results in a series of samples in which both automated and manual results were available.ProcedureSets of 111 specimens, tested over a 1‐month period, had matched automated and manual ANC results available for initial retrospective analysis. An additional set of 35 specimens with ANCs of < 1.5 × 109/L were subsequently analyzed in a similar fashion. Automated ANC results were obtained with a Cell‐Dyn 3500® (Abbott Diagnostics, Santa Clara, CA, USA) automated hematology analyzer, and manual ANC results were obtained using 100 cell differentials performed by 1 of 13 medical technologists. Results were tabulated and analyzed using standard linear regression and scatter plot analyses.ResultsOf the initial 111 specimens, automated ANC values ranged from 0.16–14.2 × 109/L (median = 2.6 × 109/L), as compared with 0.24–13.9 × 109/L (median 3.0 × 109/L) for manual ANC values (R2 = 0.99; SE = 0.49). Differences between the ANC values ranged from −55 to + 33% (SD = 14%) of the manual value. Of the second set of 35 specimens, regression analysis yielded an R2 value of 0.92, with a SE of 0.11. Both data sets yielded acceptable degrees of variation on scatter plot analyses.ConclusionsAutomated ANC values appear adequate for determining suitability for chemotherapy and lessen the turnaround time between specimen phlebotomy and result verification. Med Pediatr Oncol 2002;38:183–186. © 2002 Wiley‐Liss, Inc.

Keywords

Analysis of Variance, Time Factors, Neutrophils, Patient Selection, Antineoplastic Agents, Sensitivity and Specificity, Automation, Leukocyte Count, Neoplasms, Linear Models, Humans, Child, Retrospective Studies

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    8
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
8
Average
Top 10%
Average
Related to Research communities
Cancer Research
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!