Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Medical Physicsarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Medical Physics
Article
Data sources: UnpayWall
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Medical Physics
Article . 2020 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
Medical Physics
Article . 2020
versions View all 2 versions
addClaim

Estimating patient water equivalent diameter from CT localizer images – A longitudinal and multi‐institutional study of the stability of calibration parameters

Authors: Da Zhang; Xinming Liu; Xinhui Duan; Alexander A. Bankier; John Rong; Matthew R. Palmer;

Estimating patient water equivalent diameter from CT localizer images – A longitudinal and multi‐institutional study of the stability of calibration parameters

Abstract

PurposeWater equivalent diameter (WED) is a robust patient‐size descriptor. Localizer‐based WED estimation is less sensitive to truncation errors resulting from limited field of view, and produces WED estimates at different locations within one localizer radiograph, prior to the initiation of axial scans. This method is considered difficult to implement by the clinical community due to the necessary calibration between localizer pixel values (LPV) and attenuation, and the unknown stability of calibration results across scanners and over time. We investigated the stability of calibration results across 25 computed tomography (CT) scanners from three medical centers, and their stability over 3 ∼ 29 months for 14 of those scanners.MethodsLocalizer and axial images of ACR and body computed tomography dose index phantoms were acquired, using routine clinical techniques (120 kV and lateral localizers) on each of the 25 CT scanners: 8 GE scanners (CT750HD, VCT, and Revolution), 8 Siemens scanners (Definition AS, Force, Flash, and Edge), 5 Canon scanners (Aquilion‐One, Aquilion‐Prime80, and Aquilion‐64), and 4 Philips scanners (iCT 256, iQon, and Ingenuity). By associating axial images with the corresponding localizer lines, the relationship between the scaled water equivalent area (WEA) and averaged LPV were established through regression analysis.ResultsLinear relationships between the scaled WEA and the averaged LPV were observed in all 25 CT scanners (). Calibration parameters were similar for CT scanners from the same vendor: the coefficients of variation (COV) were ≤ 1% in all four vendor groups for the calibration slope, and < 7% for the intercept. By analyzing the deviation of WED resulted from errors in the calibration slope or intercept alone, we derived the tolerance ranges for the slope or intercept for a given WED error level. The variation of slope and intercept from different CT scanners of the same vendor introduced <±2.5% error in the estimated WED for subjects of 20 and 30‐cm WED. The calibration parameters remained stable over time, with the maximum deviations all within the boundary values that introduce ±2.5% error in the estimated WED for subjects of 20 and 30‐cm WED.ConclusionsThe stability in calibration results among CT scanners of the same vendor and over time demonstrated the feasibility of implementing WED estimation for routine clinical use.

Keywords

Phantoms, Imaging, Calibration, Humans, Water, Longitudinal Studies, Tomography, X-Ray Computed

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    4
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
4
Top 10%
Average
Top 10%
bronze