
pmid: 19243053
AbstractPurposeTo construct a temperature‐controlled diffusion phantom with known diffusion properties and geometry in order to facilitate the comparison and optimization of diffusion sequences with the objective of increasing the precision of experimentally derived diffusion parameters.Materials and MethodsA temperature‐stabilized diffusion phantom made up of two crossing strands of hydrophobic polyethylene fibers was constructed. Reproducibility and temperature dependence of several diffusion parameters was investigated and compared with computer simulations. Furthermore, in order to stimulate actual use, the precision of measurement of different diffusion‐encoding schemes was compared using bootstrap analysis.ResultsThe measured values of the diffusion parameters are highly reproducible and feature strong temperature dependence which is reproduced in simulations, underlining the necessity of a temperature‐stabilized environment for quality control. The exemplary application presented here demonstrates that the phantom allows comparing and optimizing different diffusion sequences with regard to their measurement precision.ConclusionThe present work demonstrates that the diffusion phantom facilitates and improves the comparison and quality control of diffusion sequences and the ensuing parameters. The results show that an accurate temperature control is a vital prerequisite for highly reproducible calibration measurements. As such, the phantom might provide a valuable calibration tool for clinical studies. J. Magn. Reson. Imaging 2009;29:692–698. © 2009 Wiley‐Liss, Inc.
Quality Control, Phantoms, Imaging, Temperature, Reproducibility of Results, 610 Medicine & health, 170 Ethics, Diffusion Magnetic Resonance Imaging, Polyethylene, Radiology Nuclear Medicine and imaging, Image Processing, Computer-Assisted, 2741 Radiology, Nuclear Medicine and Imaging, 10237 Institute of Biomedical Engineering, Computer Simulation, 610 Medicine & health, Hydrophobic and Hydrophilic Interactions, Algorithms
Quality Control, Phantoms, Imaging, Temperature, Reproducibility of Results, 610 Medicine & health, 170 Ethics, Diffusion Magnetic Resonance Imaging, Polyethylene, Radiology Nuclear Medicine and imaging, Image Processing, Computer-Assisted, 2741 Radiology, Nuclear Medicine and Imaging, 10237 Institute of Biomedical Engineering, Computer Simulation, 610 Medicine & health, Hydrophobic and Hydrophilic Interactions, Algorithms
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 32 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
