image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Journal of Biomedica...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Journal of Biomedical Materials Research Part A
Article . 2003 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
versions View all 2 versions
addClaim

Fracture toughness of human dentin

Authors: Nanako, Iwamoto; N Dorin, Ruse;

Fracture toughness of human dentin

Abstract

AbstractThe purpose of this study was to determine the fracture toughness (KIC) of human dentin and to test the null hypothesis that KIC is not affected by the orientation of dentinal tubules relative to the plane of crack propagation. Triangular prisms (4 × 4 × 4 × 8 mm) were obtained from human molars and tested using the notchless triangular prism (NTP) specimen KIC test. Dentin prisms were prepared so that the plane of crack propagation would have three different orientations relative to the orientation of dentinal tubules: perpendicular (PE), parallel aligned (PAA), and parallel transverse (PAT). The prepared specimens were secured in the specimen holder and loaded in tension until fracture or crack arrest. The maximum load recorded was used to calculate KIC. There was no significant difference between the KIC of PAA specimens (1.97 ± 0.17 MPa/m1/2) and PAT (2.02 ± 0.18 MPa/m1/2). The KIC for the PE specimens (1.13 ± 0.36 MPa/m1/2) was significantly lower. The SEM images of the fractured surfaces showed distinct differences that were correlated with the determined KIC values. The fractured surfaces of PAA and PAT specimens were rougher compared to PE specimens. Both the hyper mineralized peritubular dentin and the orientation of collagen fibrils surrounding the tubules could be responsible for the significant differences in KIC. The results of this study identified a significant anisotropy of dentin with respect to its KIC. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 66A: 507–512, 2003

Related Organizations
Keywords

Dentin, Materials Testing, Microscopy, Electron, Scanning, Humans

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    83
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
83
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!