Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Energy Science &...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Energy Science & Engineering
Article . 2025 . Peer-reviewed
License: CC BY
Data sources: Crossref
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Energy Science & Engineering
Article . 2025
Data sources: DOAJ
versions View all 2 versions
addClaim

Effect of Wall, Roof, and Window‐to‐Wall Ratio on the Cooling and Heating Load of a Building in India

Authors: Asim Ahmad; Om Prakash; L. S. Brar; Kashif Irshad; S. M. Mozammil Hasnain; Prabhu Paramasivam; Abinet Gosaye Ayanie;

Effect of Wall, Roof, and Window‐to‐Wall Ratio on the Cooling and Heating Load of a Building in India

Abstract

ABSTRACTThis study examines the impact of various combinations of walls, roofs, and window‐to‐wall ratios (WWRs) on the cooling and heating loads of residential buildings in India's composite climatic zone. Utilizing EnergyPlus and eQuest simulations, the thermal performance of three building types is analyzed across 32 cases involving two types of walls (W1, W2), roofs (R1, R2), and WWRs of 10%, 20%, 30%, and 40%. The results indicate that Case 29 (W2 R2 N2 WWR1), characterized by a north‐facing orientation, square‐shaped design, and a 10% WWR, achieves the lowest cooling and heating loads among all configurations. Specifically, in Building 1, this configuration reduces cooling loads by 26.0% (from 204 to 151 kBTU/h) and heating loads by 28.6% (from 224 to 160 kBTU/h) compared to the highest load scenario, Case 4 (W1 R1 N1 WWR4, west‐facing orientation, square‐shaped design, and 40% WWR). Similar trends are observed for Buildings 2 and 3. These findings underscore the critical role of optimizing building envelope parameters, particularly orientation, shape, and WWR, in achieving significant energy savings. The insights provided by this study can aid architects, engineers, and policymakers in designing energy‐efficient residential buildings.

Keywords

Technology, T, Science, Q, solar energy, window‐to‐wall ratio, energy efficiency, building envelope, heating and cooling loads

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    12
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
12
Top 10%
Average
Top 10%
gold