Abstract Aims This study aimed to investigate the clinical impact of pre-procedural left atrial strain (LAS) in patients undergoing permanent pacemaker implantation (PPI). Methods and Results This single-centre retrospective study enrolled 434 patients who were admitted for transvenous PPI between 2010 and 2020. After excluding patients with persistent atrial fibrillation, PPI for complete atrioventricular block, severe valvular disease, history of open-heart surgery and those without LAS data, 172 patients were analysed. The LAS was measured using commercially available software to calculate the average strain value of the apical four- and two-chamber views before PPI. The primary composite endpoint was hospitalization due to heart failure or cardiovascular death. Cox proportional hazard models were used to evaluate risk factors for the primary composite endpoint. The mean patient age was 78 ± 8 years, and 42% of the patients were men. PPI was performed for sick sinus syndrome in 64% and second-degree atrioventricular block in 36% of the patients. The pre-procedure left atrial reservoir strain (LASr) was 28 ± 11%. The median follow-up period was 4.7 years, and the primary endpoint was observed in 23 (13%) patients. In multivariate Cox proportional risk analysis, LASr was independently associated with the primary composite endpoint (hazard ratio, 1.08 per 1% decrease; 95% confidence interval, 1.02–1.15; P = 0.007). The receiver operating characteristic curve of the LASr for the primary composite endpoint showed a cutoff value of 21% (area under the curve 0.657, P = 0.004). The prognostic impact of LASr was consistent with that of sick sinus syndrome and atrioventricular block. Conclusions A decreased pre-procedure LASr was associated with long-term adverse outcomes after PPI use.
Male, Heart Failure, Sick Sinus Syndrome, Pacemaker, Artificial, left atrial strain, heart failure, pacemaker, Risk Factors, Echocardiography, RC666-701, echocardiography, Diseases of the circulatory (Cardiovascular) system, Humans, Original Article, Female, Atrial Function, Left, Heart Atria, Atrioventricular Block, Aged, Retrospective Studies, Follow-Up Studies
Male, Heart Failure, Sick Sinus Syndrome, Pacemaker, Artificial, left atrial strain, heart failure, pacemaker, Risk Factors, Echocardiography, RC666-701, echocardiography, Diseases of the circulatory (Cardiovascular) system, Humans, Original Article, Female, Atrial Function, Left, Heart Atria, Atrioventricular Block, Aged, Retrospective Studies, Follow-Up Studies
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |