doi: 10.1002/eej.23435
AbstractThe paper is proposed approximate formulas of the ac resistance of lead wires and coils which made by using copper clad aluminum (CCA) wires. There are the frequency range that the ac resistance of CCA wires is lower than it of cupper solid wires for lead wires and coils of an electrical equipment. It is shown that the application of CCA wires is economical as comparing with copper solid wires, if the design is due to successful calculation in the electrical equipment. The measured resistance is compared with the formula. CCA wires is an example of multiple conductors which shall be expected to apply in future.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |